How Shipping Scales Work

Electronic shipping scales can use a load cell, a sensor that responds to force with an electrical signal. An indicator processes the signal into a weight reading. A common strain-gauge design senses tiny elastic deformations. Tare changes the result by excluding a selected container’s weight.

By: Review Streets Research Lab
Updated: November 25, 2026
Explainer · 8–10 min read
A plain sealed cardboard parcel centered on the metal platter of a shipping scale at a packing bench.
What you’ll learn

Make sense of the weighing result

A weight indication starts with a physical load. Understanding it also requires knowing which weight the display represents.

  • How an applied load reaches an electronic weight indication.
  • What happens inside a common strain-gauge sensing design.
  • Why empty-platform zero and a tared zero have different meanings.
  • How gross and net distinguish the whole load from its contents.
  • How capacity differs from the displayed step.
  • What a stability indicator actually tells you.
  • Where physical weighing ends and carrier rating begins.

Tip: Read the unit beside the number: pounds, kilograms and pounds and ounces are different ways of expressing a weight.

Key definitions

Six terms behind the number

A load-cell signal becomes a weight value; tare determines whether a container is excluded.

Load cell

A sensor that converts applied force into an electrical signal for weighing.

  • Common design: Strain-gauge cells are widely used, but other sensing technologies exist.
  • Elastic element: In this design, the sensing body deforms under load and returns when unloaded.
  • Indicator: Electronics process the cell’s signal into the displayed weight.

Zero

For normal weighing on Avery Weigh-Tronix’s ZP2XX, zero references an empty platter.

  • Starting point: Normal weighing adds the item after establishing that reference.
  • Status: Gross and Net identify whether pushbutton tare is active.
  • Bounded adjustment: Its manual zero adjustment has a defined range.

Tare

The empty container’s weight, or its deduction from a gross weight.

  • Display effect: Taring with a container present resets the indicated value to zero.
  • Result: The following contents reading excludes that container’s weight.
  • Physical load: The container still uses part of the scale’s total capacity.

Gross and net

Gross includes container and contents; net accounts for tare.

  • Gross load: Packaging and product both contribute to the total.
  • Net result: Tare is accounted for in the net result.
  • Parcel context: USPS domestic guidance includes packing materials in package weight.

Capacity

The specified upper load limit for weighing.

  • Total load: Taring a container does not remove it from that limit.
  • Model rating: Brecknell lists 165 lb for the PS165 and 330 lb for the PS330.
  • Tare range: OHAUS’s EU Courier i-C52M50R specifies tare by subtraction up to capacity.

Scale division

The smallest increment a digital display can indicate.

  • Other names: Readability and resolution are also used for this displayed step.
  • Unit-specific example: The EU Courier i-C52M50R lists 0.05 lb or 0.02 kg readability.
  • Accuracy distinction: Display step size differs from agreement with the actual weight.

Tip: Treat the unit and displayed increment as part of the reading, rather than reading the digits alone.

The measured load

The platform carries the weighing load

Parcel weighing concerns what is physically supported by the scale. The examples here concern stationary bench weighing.

  • USPS’s domestic guidance includes packing materials in the package’s weight.
  • Load means the force applied to the weighing structure. That physical input is what the sensor responds to.
  • ZP2XX instructions require clearance between the platter and adjacent surfaces.
  • A stationary parcel still needs time to settle. Brecknell’s PS165/PS330 instructions call for a centered object and a stable reading.
  • Units give the value its meaning. The PS165/PS330 display can express weight in kilograms, pounds, or pounds and ounces.

The displayed quantity describes the applied load in the selected unit. It needs that physical and numerical context to be interpreted.

From load to signal

A small deformation becomes a readable value

Strain-gauge cells are a common design, rather than the only load-cell technology. Their operation provides a useful explanation of the conversion.

  • The sensing element flexes elastically under load. Small strain gauges bonded to it respond to the resulting stretch or compression.
  • Those gauges change electrical resistance. A bridge circuit converts the changes into a small voltage signal; conditioning electronics can amplify it.
  • An analog-to-digital converter changes a varying electrical voltage into digital values. The indicator processes the load-cell signal and represents it as weight.

The indicator’s result is a processed measurement. Other sensing designs can reach that display through different mechanisms.

What is included

Compare the weighing references

Taring can produce a zero display while the container remains physically present.

  • On the ZP2XX, adding an item to the empty, zeroed platter produces its gross indication.
  • For contents-only weighing, the DYMO M10/M25 US instructions describe taring an empty container first. Items added afterward are indicated without that container’s weight.
  • Gross includes packaging and contents. Net takes the tare into account.

Contents-only net weight excludes packing that USPS includes in package weight.

Reading limits

Capacity, display steps and stability

A capacity rating sets the upper load limit. A display division sets the smallest visible step. Neither description is interchangeable with accuracy.

  • Tare reduces the displayed result, not the load carried. Adam’s tare explanation says the container and contents together must remain within capacity.
  • A finer displayed step tells you how the number changes, not how close it is to the true weight. Accuracy describes that agreement.
  • ZP2XX stability means steadiness within one division. It does not rule out a separate weighing error.

A steady display can still need investigation: Adam lists wrong units, calibration errors and obstructions among possible causes of an incorrect result.

Beyond weighing

Weight leaves other shipping questions open

UPS’s US guidance treats actual package weight and dimensions as separate inputs. The weight indication alone does not supply those dimensions.

  • Actual weight and billable weight are different terms. UPS WorldShip’s glossary defines billable weight as the greater of actual and dimensional weight.
  • Dimensional weight relates package space to its actual weight. FedEx’s US FAQ explains that Express and Ground package charges use dimensional or actual weight, whichever is greater.
  • USPS domestic postage also depends on service, distance, size and weight, with flat-rate options for Priority Mail Express and Priority Mail as an exception.

The carrier’s billable-weight basis can therefore differ from actual weight. WorldShip’s glossary makes that distinction explicit.

Reality check

Two illustrations of the boundary

Whole-package weight includes packing. Separately, actual weight and dimensional weight can lead to different carrier-rating considerations.

Hypothetical: a retailer’s packed parcel

In this hypothetical USPS shipment, a retailer’s sealed parcel is weighed with its packing included.

A separate tare exercise excludes an empty container’s weight to indicate net contents.

Hypothetical: equal weights, different sizes

Imagine two parcels with equal scale readings but different dimensions. UPS’s guidance calls for weight and dimensions separately, so equal weight does not establish equal size.

That distinction can matter under FedEx’s stated US Express and Ground package rule: it compares actual and dimensional weight. This illustration assigns neither parcel a charge or a predicted invoice.

Misconceptions

Five conclusions the number cannot support

Incorrect units, obstructions or calibration errors can produce incorrect weight values.

Does every electronic scale use identical sensing internals?

No. Strain gauges are common, but load-cell technologies work in different ways. The strain-gauge explanation here describes a design, not every scale’s construction.

Does tare create extra weighing capacity?

No. The container remains a physical load after its weight is subtracted from the display. Adam explicitly includes it when describing the capacity limit.

Do more displayed digits prove greater accuracy?

No. Readability describes display increments; accuracy concerns agreement with the actual value. Repeated readings are another property again: precision describes their consistency.

Does limited display change prove the weight is correct?

No. Motion detection identifies changing indications. Adam lists separate causes of incorrect weight, including units and calibration. Detecting limited change does not test those conditions.

Does the scale reading determine postage by itself?

No. USPS also uses service, distance and size, with flat-rate exceptions. Weight alone leaves those inputs unanswered.

Tip: Keep repeatability distinct from accuracy: consistent readings need not be close to the actual value.

FAQ

Reading situations that need a little explanation

A number can remain after unloading or turn negative because of a scale function. These examples are model-specific.

Why can the unloaded DYMO M10/M25 show a negative number?

Its US manual identifies a retained tare as one explanation after unloading. The negative value represents that deduction, rather than an object with negative weight.

Why might that DYMO display zero with an item present?

The M10/M25 US manual lists two possibilities: pressing Tare/Zero while loaded, or powering up with an item present. Its zero indication can therefore coexist with a physical load.

How can the DYMO M10 still show a parcel’s weight after removal?

Its Hold feature retains the indication for ten seconds, allowing a package that blocks the display to be removed. That is a saved reading, rather than the load currently on the platform.

Must displayed gross, net and tare add up exactly?

Not always. NIST explains that separately rounded values may fail to add up exactly at the displayed division. The rounding of the indications matters when comparing their arithmetic.

What does Count mean on a Brecknell PS165/PS330?

It estimates a quantity using a known sample of components with the same weight. This is a weighing-based count; the sample’s quantity supplies the reference.

Can a shipping scale show weight without a computer screen?

The Brecknell PS165/PS330 is one documented example: it has a separate LCD indicator and can use an AC adapter or batteries. Its weight display does not depend on a computer screen.

Why can carrier rounding differ from the scale’s displayed steps?

UPS’s US guidance rounds a fractional pound upward when entering package weight. USPS says rounding to ounces or pounds depends on the product. Those service rules are separate from the display’s increment.

Is an overload indication a usable weight above capacity?

No. The M10/M25 US manual identifies an exceeded-capacity condition and says to remove the item immediately to prevent damage. The indication supplies no weight beyond its capacity.

Tip: Read unexpected indications against the model’s own instructions; these DYMO examples have specific model scope.

Bottom line

A shipping-scale reading starts with a physical load. The indicator turns the sensor’s response into a weight value. Tare deducts a selected container’s weight.

For a USPS package, weigh the packing too. The service, distance and applicable size or flat-rate rules still determine how that measurement is used.

Next steps

Continue with Shipping Scales reading

Choose a reading format for your next question.